May cat chan khong trong nha

May cat chan khong trong nha tien tien cho cac cap dien ap 12kV, 24kV va 40.5kV voi cong nghe Cooper Edison.

Ultra-low resistance vacuum arc chambersEmbedded pole APG epoxy insulationModular spring operating mechanismSilver-plated main circuit conductorsSelf-lubricating maintenance-free bearingsUp to 50,000 mechanical operations life
VN3-12E Indoor Vacuum Circuit Breaker (12kV)

VN3-12E Indoor Vacuum Circuit Breaker (12kV)

The VN3-12E is a 12kV indoor vacuum circuit breaker providing reliable control and protection for 10kV power systems. Features ultra-low resistance vacuum arc chambers and a modular spring mechanism designed for minimal maintenance.

Rated Voltage12 kV
Rated CurrentUp to 5000 A
Rated Short-Circuit Breaking Current50 kA
VN2-24E Indoor Vacuum Circuit Breaker (24kV)

VN2-24E Indoor Vacuum Circuit Breaker (24kV)

The VN2-24E is a 24kV indoor vacuum circuit breaker providing reliable control and protection for 24kV power networks. Supports operation at altitudes up to 4,500 meters and is compatible with 12kV networks.

Rated Voltage24 kV
Rated CurrentUp to 4000 A
Rated Short-Circuit Breaking Current40 kA
VN1-40.5E Indoor Vacuum Circuit Breaker (40.5kV)

VN1-40.5E Indoor Vacuum Circuit Breaker (40.5kV)

The VN1-40.5E is a 40.5kV indoor vacuum circuit breaker for 36kV and 40.5kV power networks. Offers the highest voltage class in the VN series with 20,000 mechanical operations life and up to 3150A rated current.

Rated Voltage40.5 kV
Rated CurrentUp to 3150 A
Rated Short-Circuit Breaking Current40 kA
CE-12 Edison Indoor Vacuum Circuit Breaker

CE-12 Edison Indoor Vacuum Circuit Breaker

The CE-12 Edison series indoor vacuum circuit breaker is a flagship product featuring 50,000-cycle mechanical life and up to 5000A-50kA ratings. Designed for power grids, generation, oil & gas, metallurgy, rail transit, and infrastructure sectors.

Rated Voltage12 kV
Rated CurrentUp to 5000 A
Rated Short-Circuit Breaking Current50 kA
CEi-12 Intelligent Indoor Vacuum Circuit Breaker

CEi-12 Intelligent Indoor Vacuum Circuit Breaker

The CEi-12 is a next-generation intelligent circuit breaker with built-in online monitoring, fault diagnosis, remote control, and data transmission capabilities. Reduces maintenance costs through predictive intelligence.

Rated Voltage12 kV
Intelligence FeaturesOnline monitoring, fault diagnosis, remote control
CommunicationExternal data transmission
CVG-12 Indoor Vacuum Circuit Breaker

CVG-12 Indoor Vacuum Circuit Breaker

The CVG-12 is a mature and stable 12kV indoor vacuum circuit breaker jointly developed by Cooper and domestic R&D teams. Features advanced APG epoxy casting technology for reliable embedded pole insulation.

Rated Voltage12 kV
Insulation TechnologyAPG epoxy casting
Mounting TypeIndoor
CVG-40.5 Indoor Vacuum Circuit Breaker

CVG-40.5 Indoor Vacuum Circuit Breaker

The CVG-40.5 extends the proven CVG platform to 40.5kV voltage class, featuring the same advanced APG epoxy encapsulation technology. Jointly developed by Cooper and domestic research teams for high-voltage indoor switching.

Rated Voltage40.5 kV
Insulation TechnologyAPG epoxy casting
Mounting TypeIndoor

May cat chan khong trong nha tu NAIJI Electric

May cat chan khong trong nha trung the tu 12kV den 40.5kV voi tuoi tho co khi len den 50,000 lan. Cong nghe Cooper Edison.

La nha san xuat chuyen nghiep voi hon 35 nam kinh nghiem, NAIJI Electric san xuat san pham chat luong cao dap ung tieu chuan quoc te IEC 62271.

Tat ca san pham trai qua kiem tra nghiem ngat tai nha may truoc khi xuat hang. Chung toi cung cap ca mo hinh tieu chuan va cau hinh tuy chinh.

Cau hoi thuong gap

NAIJI Electric san xuat nhung loai may cat chan khong trong nha nao?
NAIJI Electric san xuat VN3-12E Indoor Vacuum Circuit Breaker (12kV), VN2-24E Indoor Vacuum Circuit Breaker (24kV), VN1-40.5E Indoor Vacuum Circuit Breaker (40.5kV), CE-12 Edison Indoor Vacuum Circuit Breaker, CEi-12 Intelligent Indoor Vacuum Circuit Breaker, CVG-12 Indoor Vacuum Circuit Breaker, CVG-40.5 Indoor Vacuum Circuit Breaker. Tat ca san pham san xuat theo tieu chuan IEC voi he thong quan ly chat luong ISO 9001.
Thoi gian giao hang cho may cat chan khong trong nha la bao lau?
Thoi gian giao hang tieu chuan khoang 30 ngay cho hau het cac model. Cau hinh tuy chinh co the can them thoi gian.
NAIJI Electric co san xuat OEM cho may cat chan khong trong nha khong?
Co, NAIJI Electric cung cap dich vu san xuat OEM va tuy chinh. Cong suat hang thang cua chung toi la hon 250 don vi.
may cat chan khong trong nha cua ban co nhung chung nhan gi?
San pham duoc san xuat theo he thong chat luong ISO 9001, ISO 14001 va OHSAS 18001. San pham co chung nhan CE va CCC phu hop voi tieu chuan IEC 62271.

Can Indoor VCB cho du an cua ban?

Lien he voi doi ngu ky thuat de lua chon san pham, bao gia va cau hinh tuy chinh.